A synchronizing pulse that is external to the measuring instrument such as an oscilloscope, generator, logic analyzer, etc., and normally synchronizes with the system under test is known as an external trigger signal. The oscilloscope trigger function works on the principle of feeding some of the incoming waveforms into a comparator circuit.

Oscilloscope External Trigger
A function generator has a sync output that generates a square wave that is synchronized with the function generator’s output signal. The amplitude of this square wave is usually substantial, making it easier to trigger.
You may use this signal to start the oscilloscope’s trigger by connecting the function generator’s sync output to the scope’s external trigger input and letting it trigger on that. When you look at the function generator’s output signal, the scope will always trigger, even for very low voltages, making it simpler to see these.
What Is External Trigger
External triggers, such as those found in WaveForms’ Scope instrument, work in the same way as any other trigger. However, an external trigger generates a trigger using a signal that is not generated by the acquisition instrument.
The circuit of this triggering follows a general approach. External triggering creates a tiny arc between the electrodes of the flashlamp using a step-up transformer. A thin, high-temperature trigger wire is generally wrapped around the outside of the flashlamp to lower the trigger energy required for that flashlamp.
The trigger pulse is a damped oscillation from the secondary of the transformer with a peak amplitude voltage in the range of 10 kV to 30 kV. The pulse lasts about 200 nanoseconds per inch of arc length. Because there is no switch to hold back the PFN energy, the current will flow in the flashlamp as soon as the quick, high voltage trigger pulse ionizes it.
What Is External Trigger Input
It’s sometimes required to monitor or measure a waveform that’s connected to another signal, thus external triggering is used. The external input jack receives an input voltage. This is the EXT TRIG IN BNC input on the LS1020 oscilloscope’s horizontal trigger section’s bottom right corner. The sweep is triggered by the voltage applied to this input.
What Is External Trigger in Oscilloscope
The external trigger is essentially an additional input that allows you to arrange for the scope to be triggered by a signal other than the waveform(s) you’re interested in viewing.
If you were trying to view a video signal, for example, getting the scope to trigger directly off of it may be problematic since the scope wouldn’t be able to identify the difference between the sync pulses and the basic content of the video waveform. As a result, you might use the source’s frame or line timebase signal as a trigger instead.
An oscilloscope has a vertical display mode that allows it to display an external triggering signal while the sweep-generating circuit is being activated. Without reconnection of signal wires or disrupting front-panel controls, the triggering source, level, slope, and timing can be checked or studied.
How Do You Set an External Trigger on an Oscilloscope
When we set a trigger point to a particular value and when the waveform reaches this, the trigger is fired and the scan starts, and the waveform is seen on the screen. To see how to set a trigger you’ll be able to see an area of the oscilloscope front panel that contains the trigger controls.
There are several things you can do with this such as set trigger point and trigger slope. When we see a scope screen displaying a waveform, using a trigger point control on the scope, it’s possible to alter the voltage at which the waveform triggers. To determine the trigger slope, just use the switch placed on the front panel.
What is the Oscilloscope Trigger
The trigger feature on an oscilloscope synchronizes the horizontal sweep at the correct point in the waveform. This is necessary for accurate signal identification. Trigger controls allow you to catch single-shot waveforms and stabilize repeating waveforms.
By constantly displaying the same piece of the input signal on the oscilloscope display, the trigger makes repetitive waveforms look static. The most basic and popular sort of triggering is edge triggering, which is accessible in both analog and digital oscilloscopes.
Aside from threshold triggering, which is available on both analog and digital oscilloscopes, many digital oscilloscopes have a variety of unique trigger settings that are not available on analog instruments.
Conclusion
One of the most important components of the total test instrument is the oscilloscope triggering system. With the increasing sophistication of equipment comes an increase in waveform complexity, necessitating the use of more complicated trigger systems. As a result, most contemporary oscilloscopes come with a wider range of triggering choices.